Gasboy 9852/9853           

9800A SERIES REGISTRATION FLEET DISPENSERS

  • Heavy-duty, reliable dispensing equipment designed specifically for the demanding requirements of fleet fueling.

  • Wide range of models allows you to match the equipment to the job, not the job to the equipment.

  • 15 to 50 GPM (57 LPM to 188 LPM) models

  • Suction pumps or remote dispensers

  • Single or twin hoses

  • Large 1" (2.5cm) backlighted LCD display provides easy viewing

  • Simple reliable electronics mean low maintenance.

  • Weights and Measures sealable for the resale of fuel

  • Direct connection to Gasboy CFN Systems eliminates purchase of separte CFN PumpControl Unit

  • Selectable pulse/unit output for commection of Series 1000 or other fuel control systems

  • Factory-equipped, top-mounted TopKAT fuel management system option for plug and play fuel control.

  • Methanol compatible models

  • Large choice of accessories - high hose refractors, vapor recover, filters, etc.

STANDARD FEATURES

Cabinet: Finish: Top and sides painted black. Front and back panels painted white or specify color. Black bezel with black acrylic graphic overlay on dial face. 

Construction:  Top carbon steel panel. Front, back and side hot-dipped galvanized steel panels for rust resistance. Polycarbonate bezel.

Registers:  Volume only (gallons or liters) displays. 1" (2.5 cm) backlighted LCD displays. Maximum 999.000 gallons or 9999.00 liters (9850A models: 9999.00 gallons or 9999.0 liters). Display both front and back of cabinet, except models with front load nozzle boot option only display on side with corresponding nozzle boot.

Totalizer:  Displayed on LCD by magnetic switch activation. Reads up to 999999. Battery-backed.

Pulser:  Dual phase 1000 1 with error detection

Meter:  Three-piston, positive displacement. Tested and calibrated for accuracy at any speed or pressure. (9850A Series: six-step, rotary motion, positive displacement meter.)

Pump:  Suction pump models. Quiet, efficient, rotary pump. Air eliminator built into pump casting. (9850A has separate air eliminator.)

Motor:  Suction pump models. 1/2 HP intermittent duty, 3/4 HP and 1 ½ HP continuous duty.

Voltage and Frequency:  Pump motor: 115/230VAC, 60 Hz. 50 Hz optional. Electronic register: 115VAC, 60 Hz. 230VAC and 50 Hz optional.

DC Conduit ("D"):  Provides DC conduit and junction box in lower cabinet for wiring connections to fuel control systems.

Union Connection:  1 ½" (3.8 cm) NPT. Unions provided. (9840A and 9850A models: 2" (5 cm) NPT.)

Maximum Working Pressure 50 psi.

 Actual Dimensions:  Single Base: 52 5/8" H x 25 13/16" W X 18 3/8" D (133.7cm x 65.6cm x 46.7cm)  

Twin Base: 52 5/8" H x 29 1/16" W X 18 3/8" D (133.7cm x 73.8cm x 46.7cm)

Exception: 9840A models have twin-size cabinet. Front load nozzle boot option extends out from base: nozzle boot only - 6" (15.2 cm); nozzle boot w/ nozzle - 10" (25.4 cm).

 Packaging Dimensions:  Standard: 67”H x 38”W x 25”D (170cm x 97cm x 64cm)  

Front Load: 67”H x 38”W x 37”D) (170cm x 97cm x 64cm)  

Approvals:  UL Listed. FCC. Sealable by U.S. Weights and Measures for the resale of fuel for applications involving the contracted periodic billing of the fuel dispensed.  

Options:  Note: The options model number suffix is shown in quotes within the parentheses (e.g., model number 9850A-DS indicates equipped with satellite piping option).

 Display Battery Backup ("B"):  For reselling applications only. Displays the last transaction for 15 minutes after power failure. Includes heater for cold temperatures.

 Front Load Nozzle Boot ("Z"):  Relocates standard side-oriented nozzle boot to front of cabinet for lane-oriented fueling applications.

 Internal Filter Adapter ("F"):  Provides adapter inside the cabinet for a filter element to help ensure product purity. Specify standard or high flow and element type. Not available for 9853AHC-D, 9840A-D Series, 9850A-D Series, nor the following with PP option: 9852ATW2-D, 9853ATW2-D, 9853ATW1M-D.

Satellite Piping ("S"):  Provides internal piping and union for connecting to a satellite dispenser for convenient fueling of saddle tanks. Available on remote dispensers and 9850A-D.

Slowdown Valve ("PP"):  Reduces delivery to a slow flow for accurate preset shut-off by fuel control systems. Standard on dispenser models and 9852ATW1-D.

 Stainless Steel Panels:  Provide durable finish. All stainless steel panels ("SS"). Stainless steel front and back panels only ("SSA"). Stainless steel top and sides only ("SSTS").

Topkat Mounting Kit ("D9"):  Includes DC conduit, junction box and pump-mounting hardware for the TopKAT fuel management system.

 Liter Measure ("R"):  Displays volume in liters.

230Vac Power ("2"):  230VAC register electronics for international locations.

50 HZ Power (“5”):  50 Hz register electronics for international locations.

380VAC Power (“3”):  380VAC, three-phase motor operation and 230VAC register electronics for international locations. Not available on 9850A or any 9852A models.

Accessories:   Note: The accessory part number is shown in parentheses after the accessory name, or in the description if there are multiple options.

Aboce Ground Tank Kits:   Required for aboveground tank suction pump installations to prevent product from leaking from the air eliminator vent. Use Pressure Regulating Valve (048577) for 9852A-D, 9853A-D, 9852ATW1-D, 9852ATW2-D and 9853ATW2-D models. TW2 models require two valves. Use Aboveground Tank Kit

(032060) for 9850A-D. 9840A-D, 9853AHC-D and

 9853ATW1 M-D are not recommended for use with aboveground tanks.

 Card System Interface - CFN (CO6468):  RS485 interface for direct connection to Gasboy CFN System.

Card System Interface - Pulse Output (CO6467):   Selectable pulse/gallon outputs for Gasboy Series 1000, FleetKey and other fuel control systems.

 Filter Kits - External:  Help ensure product purity. Single or dual elements kits for high flow. Standard, methanol or hydrosorb elements are available.  

Light (115V - C07181; 230V – C07182):  Illuminates product panels and register areas. Two fluorescent bulbs.

 Submersible Pump Direct Drive Relay:  For the direct drive of submersible pumps up to æ hp at 115VAC or 1-1/2 hp at 230 VAC. Alternative to external relay box. Single (C06478) or twin (C06469) relays.

 Totalizer - Mechanical:  Mechanical non-resettable totalizer. Located on side panel. Reads up to 9999999.9. Required for resale applications.

For Additional Information - Download the PDF Document.

  