9800A SERIES REGISTRATION FLEET DISPENSERS
Heavy-duty, reliable dispensing equipment designed specifically for the demanding requirements of fleet fueling.
Wide range of models allows you to match the equipment to the job, not the job to the equipment.
15 to 50 GPM (57 LPM to 188 LPM) models
Suction pumps or remote dispensers
Single or twin hoses
Large 1" (2.5cm) backlighted LCD display provides easy viewing
Simple reliable electronics mean low maintenance.
Weights and Measures sealable for the resale of fuel
Direct connection to Gasboy CFN Systems eliminates purchase of separte CFN PumpControl Unit
Selectable pulse/unit output for commection of Series 1000 or other fuel control systems
Factory-equipped, top-mounted TopKAT fuel management system option for plug and play fuel control.
Methanol compatible models
Large choice of accessories - high hose refractors, vapor recover, filters, etc.
STANDARD FEATURES
Cabinet: Finish: Top and sides painted black. Front and back panels painted white or specify color. Black bezel with black acrylic graphic overlay on dial face.
Construction: Top carbon steel panel. Front, back and side hot-dipped galvanized steel panels for rust resistance. Polycarbonate bezel.
Registers: Volume only (gallons or liters) displays. 1" (2.5 cm) backlighted LCD displays. Maximum 999.000 gallons or 9999.00 liters (9850A models: 9999.00 gallons or 9999.0 liters). Display both front and back of cabinet, except models with front load nozzle boot option only display on side with corresponding nozzle boot.
Totalizer: Displayed on LCD by magnetic switch activation. Reads up to 999999. Battery-backed.
Pulser: Dual phase 1000 1 with error detection
Meter: Three-piston, positive displacement. Tested and calibrated for accuracy at any speed or pressure. (9850A Series: six-step, rotary motion, positive displacement meter.)
Pump: Suction pump models. Quiet, efficient, rotary pump. Air eliminator built into pump casting. (9850A has separate air eliminator.)
Motor: Suction pump models. 1/2 HP intermittent duty, 3/4 HP and 1 ½ HP continuous duty.
Voltage and Frequency: Pump motor: 115/230VAC, 60 Hz. 50 Hz optional. Electronic register: 115VAC, 60 Hz. 230VAC and 50 Hz optional.
DC Conduit ("D"): Provides DC conduit and junction box in lower cabinet for wiring connections to fuel control systems.
Union Connection: 1 ½" (3.8 cm) NPT. Unions provided. (9840A and 9850A models: 2" (5 cm) NPT.)
Maximum Working Pressure 50 psi.
Actual Dimensions: Single Base: 52 5/8" H x 25 13/16" W X 18 3/8" D (133.7cm x 65.6cm x 46.7cm)
Twin Base: 52 5/8" H x 29 1/16" W X 18 3/8" D (133.7cm x 73.8cm x 46.7cm)
Exception: 9840A models have twin-size cabinet. Front load nozzle boot option extends out from base: nozzle boot only - 6" (15.2 cm); nozzle boot w/ nozzle - 10" (25.4 cm).
Packaging Dimensions: Standard: 67”H x 38”W x 25”D (170cm x 97cm x 64cm)
Front Load: 67”H x 38”W x 37”D) (170cm x 97cm x 64cm)
Approvals: UL Listed. FCC. Sealable by U.S. Weights and Measures for the resale of fuel for applications involving the contracted periodic billing of the fuel dispensed.
Options: Note: The options model number suffix is shown in quotes within the parentheses (e.g., model number 9850A-DS indicates equipped with satellite piping option).
Display Battery Backup ("B"): For reselling applications only. Displays the last transaction for 15 minutes after power failure. Includes heater for cold temperatures.
Front Load Nozzle Boot ("Z"): Relocates standard side-oriented nozzle boot to front of cabinet for lane-oriented fueling applications.
Internal Filter Adapter ("F"): Provides adapter inside the cabinet for a filter element to help ensure product purity. Specify standard or high flow and element type. Not available for 9853AHC-D, 9840A-D Series, 9850A-D Series, nor the following with PP option: 9852ATW2-D, 9853ATW2-D, 9853ATW1M-D.
Satellite Piping ("S"): Provides internal piping and union for connecting to a satellite dispenser for convenient fueling of saddle tanks. Available on remote dispensers and 9850A-D.
Slowdown Valve ("PP"): Reduces delivery to a slow flow for accurate preset shut-off by fuel control systems. Standard on dispenser models and 9852ATW1-D.
Stainless Steel Panels: Provide durable finish. All stainless steel panels ("SS"). Stainless steel front and back panels only ("SSA"). Stainless steel top and sides only ("SSTS").
Topkat Mounting Kit ("D9"): Includes DC conduit, junction box and pump-mounting hardware for the TopKAT fuel management system.
Liter Measure ("R"): Displays volume in liters.
230Vac Power ("2"): 230VAC register electronics for international locations.
50 HZ Power (“5”): 50 Hz register electronics for international locations.
380VAC Power (“3”): 380VAC, three-phase motor operation and 230VAC register electronics for international locations. Not available on 9850A or any 9852A models.
Accessories: Note: The accessory part number is shown in parentheses after the accessory name, or in the description if there are multiple options.
Aboce Ground Tank Kits: Required for aboveground tank suction pump installations to prevent product from leaking from the air eliminator vent. Use Pressure Regulating Valve (048577) for 9852A-D, 9853A-D, 9852ATW1-D, 9852ATW2-D and 9853ATW2-D models. TW2 models require two valves. Use Aboveground Tank Kit
(032060) for 9850A-D. 9840A-D, 9853AHC-D and
9853ATW1 M-D are not recommended for use with aboveground tanks.
Card System Interface - CFN (CO6468): RS485 interface for direct connection to Gasboy CFN System.
Card System Interface - Pulse Output (CO6467): Selectable pulse/gallon outputs for Gasboy Series 1000, FleetKey and other fuel control systems.
Filter Kits - External: Help ensure product purity. Single or dual elements kits for high flow. Standard, methanol or hydrosorb elements are available.
Light (115V - C07181; 230V – C07182): Illuminates product panels and register areas. Two fluorescent bulbs.
Submersible Pump Direct Drive Relay: For the direct drive of submersible pumps up to æ hp at 115VAC or 1-1/2 hp at 230 VAC. Alternative to external relay box. Single (C06478) or twin (C06469) relays.
Totalizer - Mechanical: Mechanical non-resettable totalizer. Located on side panel. Reads up to 9999999.9. Required for resale applications.
For Additional Information - Download the PDF Document.